Cable exits
A cable holds and stays sealed if it is held far enough into the resin and exits at the right place.
In short
The mold closes around each cable where it leaves the part. The cable must therefore exit level with the parting line, straight, and be surrounded by resin over some length inside.
Why it matters
A cable that exits away from the parting line or at a slant gets pinched by the mold, or lets resin escape. A cable surrounded over too short a length can slide when pulled, and moisture can follow the jacket.
What you can do
- Align the cable axis with the parting line where it exits.
- Extend the overmold along the cable so it is better held.
- Space neighboring cables apart so resin can flow between them.