What your drawings should specify

What a drawing does not say, the shop has to assume: better to write it down.

Left, a dimensioned drawing with its wiring table filled in. Right, the same drawing with no dimension and an empty table: everything is left to assumption.
Left, a dimensioned drawing with its wiring table filled in. Right, the same drawing with no dimension and an empty table: everything is left to assumption.

In short

A cable or harness is built from its drawings. The industry standard for the acceptance of cables and harnesses, IPC/WHMA-A-620, leaves several choices to the drawing or to the agreement between you and the manufacturer: the level of requirement (three classes, from everyday products to products that must not fail), lengths, marking, tests.

What we apply by default

If your drawing or order says nothing else:

  • Class 1 of the IPC/WHMA-A-620 standard, the least demanding of the three: the assembly must perform its function.
  • Tests on every assembly: continuity of each conductor and no short circuit.
  • Withstand voltage and insulation resistance, which classes 2 and 3 can require: we do not perform these tests at this time. If your product needs them, let's talk before you order.
  • Lengths: the tolerance is on the plus side only. A cable may be delivered slightly longer than its dimension, never shorter.
  • Marking: none, unless the drawing asks for it.

Why it matters

With no indication from you, our default conditions apply: they suit an everyday product, not necessarily yours. A missing detail is discovered on the first part, when a correction costs the most.

What you can do

Is your design not final yet?

This is the best time to talk about it. Upload your drawings to the portal, even as drafts, and say in your notes that the board or the wiring can still change: a Fillio specialist looks at the connection with you.