Choosing a cable that overmolds well
The resin comes in hot and has to bond to the cable: the material of its jacket and of its insulation decides both.
In short
Inside the overmold, the cable jacket is stripped away: the conductors, already heated by soldering, are in direct contact with the hot resin. Where the cable exits, the resin closes onto the jacket. So the insulation must withstand the heat of injection and the resin must bond to the jacket; the cable's data sheet gives the material and the maximum temperature of each.
Why it matters
Thin insulation meant for a moderate temperature can soften or melt during injection: two conductors, or a conductor and the shield, then touch inside the part, where nothing shows and nothing can be repaired. And if the resin does not bond to the jacket, the cable can slip and moisture can follow it to the solder joints. With such a cable, no amount of care in assembly guarantees the result.
What you can do
- Read on the data sheet the material and the maximum temperature of the jacket and of the conductor insulation.
- Prefer the materials that polyamide resin bonds to: PVC, polyurethane (PUR, TPU) or polyamide.
- Avoid polyethylene, silicone and fluoropolymers (PTFE, FEP): the resin bonds poorly to them.
- For a thermoplastic elastomer (TPE) or a polypropylene, plan a test on a sample.
- Send us the data sheet or a sample of the cable before you settle on it: we check it with you.